Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance

Large Image :  Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Model Number: FCMU
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 908pcs/month
Detailed Product Description
Usage: Force Measurement Measure Direction: Tension And Compression
Type: High Resistance Load Cell Force Range: 50kg 100kg 200kg 500kg 1t 2t 3t
Material: Stainless Steel Connection: M16 Threaded Hole
Output: Analog Sensor

Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance

High resistance Load Cell FCMU is produced based on strain gauge technology intended for both tension and compression force measurement. Pancake Load Cell FCMU offers 0-50kg / 0-100kg / 0-200kg / 0-500kg / 0-1000kg / 0-2000kg / 0-3000kg seven rated measuring ranges. The low profile load cell FCMU incorporates an M16x1.5 threaded hole running through the center of the transducer which can be used to mount attachments such as load buttons or eye bolts to fit different applications. Spoke Type Load Cell FCMU utilizes 2000 ohms high resistance strain gauges to deliver better stability while consuming less power compared to traditional loadcells with 350 ohms or 700 ohms resistance. Stainless steel load cell FCMU is applicable for both static and dynamic force measurement. You may find pancake load cell FCMu suitable for force measurement in injection-molding machines, press machines and material testing equipment and so on. Model FCMU can also be modified or customzied as per requirements of our clients.

high resistance load cell

Specifications

Capacity

50kg / 500N / 110lb

100kg / 1kN / 220lb

200kg / 2kN / 450lb

500kg / 5kN / 1.1klbs

1000kg / 10kN / 2.2klb

2000kg / 20kN / 4.5klb

3000kg / 30kN / 6.6klb

Rated output 2.0mV/V
Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.1% R.O.
Hysteresis ±0.1% R.O.
Nonrepeatability ±0.05% R.O.
Creep(5min) ±0.05% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.05% R.O./10oC
Temperature shift span ±0.05% R.O./10oC
Input resistance 2000±100 ohms
Output resistance 2000±100 ohms
Insulation resistance >2000M ohms
Ingress protection IP65
Material of element Stainless steel
Cable Ø3*3000mm 4-core shielded cable
Wiring code

Red--Excitation+  Black--Excitation-
Green--Signal+  White--Signal-

 

Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance
load cell with high resistance
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of stainless steel pancake load cell FCMU is normally around 2.0mV/V.
Power supply of spoke type load cell FCMU is normally within 3-15V.
Load / Capacity is within 0-1.
So the output range of high resistance load cell FCMU is normaly within -30mV...+30mV.
Example: Pancake Load Cell FCMU-200kg with 2.0mV/V power by 10V DC,the output range is -20mV...+205mV proportional to the applied load.
Load cell + Signal amplifier:
The mV output from the loadcell transducer sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
Example: Compression Load Cell FCMU-500kg working with 0-10V amplifier,the load-output relationship will be 0-500kg compressive load VS 0-10V output,0V output corresponds to 0kg, 1V output corresponds to 50kgf compression load, 5V output corresponds to 250kgf load, and so on.

Low Profile Compression Load Cell 50kg 100kg 200kg 500kg 1t 2t With High Resistance

force sensor with high resistance

Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us