Product Details:
Payment & Shipping Terms:
|
Usage: | Compression Force Measurement | Type: | Smallest Button Load Cell |
---|---|---|---|
Output: | Analog Sensor | Capacity: | 5kg 10kg 20kg 50kg |
Feature: | Miniature Size | Material: | Stainless Steel |
Diameter: | 10mm | Height: | 6mm |
Smallest Compression Load Cell 5kg 10kg 20kg 50kg Button Type Load Sensor
Smallest Button Type Load Cell Force Sensor FC10C is made of stainless steel based on metal foil stain gauge technology intended for compression force measurement. Smallest Load Cell FC10C offers 0-5kg / 0-10kg / 0-20kg / 0-50kg four rated measuring ranges to choose from.Small size compression load cell FC10C is featured with only 10mm outer diameter and 6mm total height which makes it extremely suitable for compression force measurement applications with limited mounting space.Typical applications for transducer FC10C are such as clamping force measuremen, force overload protection, load distribution analysis, pressing die force measurement, auto equipment, assembly line and so on. Miniature Force Sensor FC10C can also be modified or customized as per client's request.
Dimensions(in "mm")
Specifications
Capacity |
5kg / 50N / 11lb 10kg / 100N / 22 lb 20kg / 200N / 44lb 50kg / 500N / 110lb |
Rated output | 1.0mV/V |
Excitation | 3-10V |
Zero balance | ±0.05mV/V |
Nonlinearity | ±1% R.O. |
Hysteresis | ±1% R.O. |
Nonrepeatability | ±0.5% R.O. |
Creep(3min) | ±0.5% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.05% R.O./oC |
Temperature shift span | ±0.05% R.O./oC |
Input resistance | 900±100 ohms |
Output resistance | 900±100 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP65 |
Material of element | Stainless steel |
Cable | Ø2*4000mm 4-core shielded |
Wiring code |
Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: FC10C-20kg with 1.0mV/V sensitivity powered by 3.3V DC,the output range is 0~3.3mV.
Example two: FC10C-10kg with 1.0mV/V sensitivity powered by 5V DC,the output range is 0~5mV.
Load cell + Signal amplifier:
Load cell normally outputs -30mV...+30mV which sometimes can hardly be processed directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
Example: Button Load Cell FC10C-10kg working with amplifier FSC(0-10V)-24V, the load-output relationship will be 0-10kg load VS 0-10V output, when you get 1V output,it means the current load is 1kg,when you get 5V output,it means the current load is 5kg, and so on.
Smallest Button Load Cell 5kg 10kg 20kg 50kg Compression Load Sensor
Contact Person: Mr. Tarik Lu
Tel: +86 755 84536383