Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg

Large Image :  Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Certification: CE
Model Number: FFA
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 2199pcs/month
Detailed Product Description
Usage: Compression Force Measurement Type: Cylindrical Load Cell
Connection: Flange-to-Flange Output: Analog Sensor
Capacity: 20kg 50kg 100kg 200kg 500kg 1ton 2ton

Cylindrical Compression Load Cell 1000kg Column Type Compressive Load Cell 2000kg

Flange Type Compression Load Cell FFA is made of stainless steel utilizing strain gauge technology to deliver mV/V output with maximum 0.1% non-linearity of the full scale.Tension Compression Force Sensor FFA offers 0-20kg / 0-50kg / 0-100kg / 0-200kg / 0-500kg / 0-1000kg / 0-2000kg seven rated measuring ranges to choose from, flange mounted force transducer FFA can be used for both tension and compression force measurement. Stainless steel construction, flange design, compact size, bidirectional force measurement, high accuracy, Cylindrical Load Cell FFA offers a perfect force measuring solution for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification,and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.

1000kg compression load cell 2000kg

Dimensions(Unit in "mm")

1000kg column load cell 2000kg

Ordering code Measurement Range Force direction
FFA-200N 0-200N / 0-20kg Tension/compression
FFA-500N 0-500N / 0-50kg
FFA-1kN 0-1000N / 0-100kg
FFA-2kN 0-2000N / 0-200kg
FFA-5kN 0-5000N / 0-500kg
FFA-10kN 0-10kN / 0-1000kg
FFA-20kN 0-20kN / 0-2000kg

Specifications

Capacity

200N / 20kg / 44 lbf
500N / 50kg / 110 lb
1000N / 100kg / 220 lbf

2000N / 200kg / 440 lb
5000N / 500kg / 1.1 klb
10kN / 1000kg / 2.2 klb

20kN / 2000kg / 4.4 klb

Rated output 2.0 mV/V
Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.1% of full capacity
Hysteresis ±0.1% of full capacity
Nonrepeatability ±0.05% of full capacity
Creep(5min) ±0.05% of full capacity
Safe overload 150% of full capacity
Ultimate overload 200% of full capacity
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 385±30 ohms
Output resistance 350±10 ohms
Insulation resistance >5000M ohms
Ingress protection IP62
Material of element Stainless steel
Cable Ø3*3000mm 4-core shielded
Wiring code

Red--Power input+  Black--Power input-

Green--Signal output+  White--Signal output-

 

Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of column load cell FFA is normally around 2.0mV/V.
Power supply of cylindrical load cell FFA is normally within 3-15V.
Load / Capacity is within 0-1.
So the output range of flange force sensor FFA is normally within 0-30mV(-30mV...+30mV for tension and compression force measurement).
Example one: Tension Compression Load Cell FFA-2000kg with 2.0mV/V sensitivity powered by 10V DC,the output range is -20mV...+20mV.
Example two: Tension and Compression Load Cell FFA-1000kg with 2.0mV/V sensitivity powered by 5V DC,the output range is -10mV...+10mV.

A load cell amplifier can be used to deliver -5~5V, 0-10V or 4-20mA output. Example: Cylindrical compression load cell FFA-1000kg working with -10-10V amplifier,the Force-Voltage relationship will be 0-1000kg compression load VS 0-10V output, 0-1000kg tension load VS 0-(-10V) output, the force-woltage relationship is linear regardless the measurement error.

Cylindrical Compression Load Cell 2000kg Column Type Compressive Load Cell 1000kg

2000kg compression load cell 1000kg
Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us