Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor

Large Image :  Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Certification: CE
Model Number: FFG
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 2970pcs/month
Detailed Product Description
Type: Cylindrical Load Cell Capacity: 20N 50N 100N 200N 500N 1000N 2000N
Usage: Force Measurement Force Measurement Direction: Tension And Compression
Output: Analog Sensor Mounting: Flange To Flange

Flange Type Force Transducer 2kN 1kN 500N 200N 100N 50N 20N Tension Compression Sensor

Miniature Flange-to-Flange Tension Compression Force Sensor FFG is made of stainless steel utilizing strain gauge technology to deliver maximum 0.1% non-linearity of rated output.Miniature force sensor FFG offers 0-20N / 0-50N / 0-100N / 0-200N / 0-500N / 0-1kN / 0-2kN seven rated capacities to choose from, model FFG can be used for both tension and compression force measurement. Stainless steel construction, flange design, compact size, bidirectional force measurement, high accuracy, Miniature Load Cell FFG offers a perfect mixture for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification,and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.

Flange-to-flange load cell 200kg 100kg 50kg

Dimensions(Unit in "mm")

Flange type force sensor tension compression

Ordering code Measurement Range Force direction
FFG-20N 0-20N / 0-2kgf Tension/compression
FFG-50N 0-50N / 0-5kgf
FFG-100N 0-100N / 0-10kgf
FFG-200N 0-200N / 0-20kgf
FFG-500N 0-500N / 0-50kgf
FFG-1kN 0-1000N / 0-100kgf
FFG-2kN 0-2000N / 0-200kgf

Specifications

Capacity

20N / 50N / 100N / 200N / 500N / 1kN / 2kN
2kg / 5kg / 10kg / 20kg / 50kg / 100kg / 200kg
4.4lb / 10lb / 20lb / 45lb / 110lb / 220lbs / 450lbf

Rated output 2.0 mV/V
Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.1% R.O.
Hysteresis ±0.1% R.O.
Nonrepeatability ±0.05% R.O.
Creep(5min) ±0.05% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 350±30 ohms
Output resistance 350±5 ohms
Insulation resistance >2000M ohms
Ingress protection IP62
Material of element Stainless steel
Cable Ø3*3000mm 4-core shielded
Wiring code

Red--Excitation+   Black--Excitation-

Green--Signal+   White--Signal-

 

A Force Sensor is a transducer that converts mechanical load into mV signal proportional to the applied force.The acting force causes deformation of the measuring element,the bonded strain gage deforms accordingly which will cause the resistance change of the wheatstone bridge,under constant power supply, the output signal between Sig+ and Sig- will change proportionally,thus the load/force can be measured by measuring the output signal from the transducer.

Load cell output: = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: Flange Load Cell FFG-500N with 2.0mV/V sensitivity powered by 5V DC,the output range is -10mV...+10mV(Tension and compression).
Example two: Tension Compression Load Cell FFG-200N with 2.0mV/V sensitivity powered by 10V DC,the output range is -20mV...+20mV(Tension and compression).

A signal conditioner can be used with the load cell to deliver -5~5V, 0-10V or 4-20mA output.

Example: FFG-500N working with -5-5V amplifier,the Force-Voltage relationship will be 0-500N compression load VS 0-5V output, 0-500N tension load VS 0-(-5V) output,when you get 3V output,it means the current load is 300N compression force,when you get -2V output,it means the current load is 200N tension force,and so on.