Product Details:
Place of Origin: China
Brand Name: Forsentek
Certification: CE
Model Number: FFA
Payment & Shipping Terms:
Minimum Order Quantity: 1pc
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 2855pcs/month
Detailed Product Description
Usage: Force Measurement Theory: Thrust Load Cell
Output: Analog Sensor Capacity: 0-20kN(Selectable)
Force Direction: Tension And Compression Mounting: Flange-to-flange

Thrust force transducer 1kN/2kN/5kN/10kN/20kN actuator thrust measurement

Thurst force transducer FFA is made of stainless steel utilizing strain gauge technology intended for both tension and compression force measurement. Flange to flange force transducer FFA offers 0-200N / 0-500N / 0-1kN / 0-2kN / 0-5kN / 0-10kN / 0-20kN seven measuring ranges to choose from,high accuracy with maximum 0.1% non-linearity of the rated capacity.Force sensor has been widely used for spring testing, welding clamp force control, hand press force verification, force distribution analysis, assembly force monitoring and other industrial applications. Besides the standard size and capacities,Forsentek is also capable of and willing to provide custom design service as per client’s request.

thrust_force_transducer_1kN_2kN_5kN_10kN_20kN

Dimensions(in "mm")

actuator_thrust_measurement_transducer

Ordering code Measuring range Measure direction
FFA-200N 0~200N / 0~20kgf Tension/compression
FFA-500N 0~500N / 0~50kgf
FFA-1kN 0~1000N / 0~100kgf
FFA-2kN 0~2000N / 0~200kgf
FFA-5kN 0~5000N / 0~500kgf
FFA-10kN 0~10kN / 0~1000kgf
FFA-20kN 0~20kN / 0~2000kgf

Specifications

Capacity

200N / 20kg
500N / 50kg
1kN / 100kg

2kN / 200kg

5kN / 500kg

10kN / 1000kg

20kN / 2000kg

Rated output 2.0 mV/V
Excitation 3-15V
Zero balance ±0.05mV/V
Nonlinearity ±0.1% R.O.
Hysteresis ±0.1% R.O.
Nonrepeatability ±0.05% R.O.
Creep(5min) ±0.05% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 385±30 ohms
Output resistance 350±30 ohms
Insulation resistance >2000M ohms
Ingress protection IP62
Material of element Stainless steel
Cable Ø3*3000mm 4-core shielded
Wiring code

Red--Excitation+ Black--Excitation-

Green--Signal+ White--Signal-

 

Load Cell:A device which produces an output signal proportional to the applied weight or force.

Wheatstone Bridge:A Wheatstone bridge is a network of four resistive legs. One or more of these legs can be active sensing elements. The Wheatstone bridge is the electrical equivalent of two parallel voltage divider circuits. R1 and R2 compose one voltage divider circuit, and R4 and R3 compose the second voltage divider circuit. The output of a Wheatstone bridge is measured between the middle nodes of the two voltage dividers.

Excitation: The voltage applied to the input terminals of the load cell.

Rated Capacity: The maximum axial load the load cell is designed to measure within its specifications.

Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.

Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.

Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.

Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

Ultimate Overload: The maximum load in percent of rated capacity which can be applied without producing a structural failure.

Operating Temperature: The extremes of temperature within which a load cell will operate without permanent adverse change to any of its performance characteristics.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.

Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.

Input Resistance: The resistance of the load cell bridge circuit measured at the positive and negative excitation terminals with no load applied and with the output terminals open-circuited.

Output Resistance: The resistance of the transducer bridge circuit measured at the positive and negative signal terminals with no load applied and with the input terminals open-circuited.

Thrust force transducer 1kN/2kN/5kN/10kN/20kN actuator thrust measurement

1kN_2kN_5kN_10kN_20kN_thrust_force_measurement

Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us