Product Details:
Payment & Shipping Terms:
|
Usage: | Force Measurement | Theory: | Flange Mounted Load Cell |
---|---|---|---|
Output: | Analog Sensor | Capacity: | 50N 100N 200N 500N 1000N 2000N |
Force Direction: | Tension And Compression | Mounting: | Flange-to-flange |
Small size flanged load cell 20kg compact force transducer 200N
Flanged load cell FFG is made of stainless steel utilizing strain gauge technology to deliver maximum 0.1% non-linearity of rated output.Miniature force sensor FFG offers 0-50N / 0-100N / 0-200N / 0-500N / 0-1000N / 0-2000N six rated capacities to choose from,this model is suitable for both tension tension and compression force measurement.Stainless steel construction, flange-to-flange mounting, compact size, bidirectional force measurement, high accuracy, competitive price, miniature force sensor FFG offers a perfect mixture for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification,and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.
Dimensions(in "mm")
Ordering code | Measurement Range | Force direction |
FFG-50N | 0-50N/0-5kgf |
Tension/compression |
FFG-100N | 0-100N/0-10kgf | |
FFG-200N | 0-200N/0-20kgf | |
FFG-500N | 0-500N/0-50kgf | |
FFG-1kN | 0-1000N/0-100kgf | |
FFG-2kN | 0-2000N/0-200kgf |
Specifications
Capacity |
50N / 5kgf / 11lb |
Rated output | 2.0 mV/V |
Excitation | 3-15V |
Zero balance | ±0.05mV/V |
Nonlinearity | ±0.1% R.O. |
Hysteresis | ±0.1% R.O. |
Nonrepeatability | ±0.05% R.O. |
Creep(5min) | ±0.05% R.O. |
Safe overload | 150% F.S. |
Ultimate overload | 200% F.S. |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.02% R.O./oC |
Temperature shift span | ±0.02% R.O./oC |
Input resistance | 350±30 ohms |
Output resistance | 350±5 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP62 |
Material of element | Stainless steel |
Cable | Ø3*3000mm 4-core shielded |
Wiring code | Red--E+ Black--E- Green--S+ White--S- |
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a load sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output is normally within 1mV/V~3mV/V.
Power supply is normally within 3-15V.
Load / Capacity is within 0-1.
So the load cell output signal is normally within 0-45mV(-45mV...+45mV for bidirectional load cell).
Example one: 2.0mV/V load cell with 10V power supply,the output range is 0~20mV (-20mV...+20mV for bidirectional transducer).
Example two: 1.0mV/V load cell with 5V power supply,the output range is 0~5mV (-5mV...+5mV for bidirectional sensor).
Load cell with signal amplifier:
Load cell normally outputs -30mV...+30mV which sometimes cannot be recognized by signal processing units directly,what’s where signal conditioner is introduced which can converts mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
Example: FFG-200N working with 0-10V amplifier,the load-output relationship will be 0-200N load VS 0-10V output,it is linear within the error range.
Small size flanged load cell 20kg compact force transducer 200N