Forsentek Co., Limited

Sales & Support
Request A Quote - Email
Select Language
English
Spanish
Home ProductsDigital load cell

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output
Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output

Large Image :  Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Model Number: FDNT
Payment & Shipping Terms:
Minimum Order Quantity: 5pcs
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 4090pcs/month
Detailed Product Description
Usage: Smart Inventory Management Type: Digital Load Cell
Capacity: 100kg 200kg 300kg 500kg Structure: Single Point Loadcell
Output: RS485 Modbus RTU

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output

Digital load cell FDNT utilizes a built-in microprocessor to convert mV signal from bonded wheatstone bridge into digital output,which makes load cell sensor FDNT more stable and accurate compared to analog load cells. Digital weight sensor FDNT supports RS485 Modbus RTU protocol with 0-100kg / 0-200kg / 0-300kg / 0-500kg four rated measuring ranges to choose from, it is corner trimmed for off-center load measurement with platform sizes up to 800x800mm, temperature compensation process guarantees stable readout in a wide temperature range. Typical applications of digital load cell transducer FDNT are for example smart shelves, vending machines, unmanned stores, intelligent warehouse management system and so on.

100kg_Digital_Load_Cell_200kg
Dimensions
200kg_Digital_Weight_Sensor_500kg

200kg_Digital_Load_Cell_300kg

Specifications

Rated capacity

100kg / 200kg / 300kg / 500kg
220lbs / 440lbf / 660lb / 1.1klb

Output

RS485 (Modbus RTU)

Excitation 5-12V DC
Nonlinearity ±0.02% R.O.
Hysteresis ±0.02% R.O.
Nonrepeatability ±0.01% R.O.
Creep(30min) ±0.02% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature 0...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.02% R.O./10oC
Temperature shift span ±0.02% R.O./10oC
Ingress protection IP65
Material of element Aluminum alloy
Cable Ø5*2000mm 4-wire shielded
Wiring code

Red--Power+
Black--Power-
Green--RS485 A
White--RS485 B

 

Parameters instruction:
Non-linearity: The maximum deviation of the calibration curve from a straight line drawn between the no-load and rated outputs; expressed as a percentage of the rated output and measured on increasing load only.
Non-repeatability: The maximum difference between load cell output readings for repeated loadings under identical loading and environmental conditions.
Hysteresis: The maximum difference between load cell output readings for the same applied load; one reading obtained by increasing the load from zero and the other by decreasing the load from rated output; usually measured at half rated output and expressed in percent of rated output.
Creep: The change in load cell output occurring with specified period of time, while under load, and with all environmental conditions and other variables remaining constant; usually measured with rated load applied.

Temperature Shift Span: The change in output due to a change in load cell temperature; usually expressed as a percentage of load per degree Celsius change in temperature.
Temperature Shift Zero: The change in zero balance due to a change in ambient temperature; usually expressed in percent of rated output per degree Celsius change in temperature.
Safe Overload: The maximum load in percent of rated capacity which can be applied without producing a permanent shift in performance characteristics beyond those specified.

300kg_Digital_Load_Cell_500kg

A load cell (or loadcell) is a transducer which converts force into a measurable electrical output. Strain gauge based load cells are the most commonly used type and suitable for almost all industrial applications.Strain gauge load sensors contain wheatstone bridge within them to deliver mV output signal which is proportional to the applied load/force under constant power supply, thus the load/force can be measured by measuring the output signal from the transducer. Digital load cell FDNT outputs digital signal instead of analog signal through RS485 communication interface utilizing Modbus RTU protocol,the weight sensor was pre-calibrated before shipment and the weight value was trasmitted in hexadecimal, multiple digital load cells can be integrated together in one system,which makes digital weight transducer FDNT especially suitable for weight measurement where multiple loadcells are involved such as smart shelves,intelligent warehouse management,etc.

Digital Load Cell 100kg 200kg 300kg 500kg Load Cell With RS485 Output

 500kg_Digital_Load_Cell_100kg

Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us