Forsentek Co., Limited

Sales & Support
Request A Quote - Email
Select Language
English
Spanish
Home ProductsCompression load cell

Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg

Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg

Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg
Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg

Large Image :  Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Model Number: FCU
Payment & Shipping Terms:
Minimum Order Quantity: 2pcs
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 2966pcs/month
Detailed Product Description
Usage: Force Measurement Measure Direction: Compression And Traction
Force Range: 2kg 5kg 10kg 20kg 50kg 100kg Material: Stainless Steel
Connection: M4 Threaded Hole Output: Analog Load Cell

Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg

Small Size Compression Load Cell FCU is made from stainless steel based on strain gauge technology delivering unamplified mV output which is proportional to the load applied. Small Size Pancake Load Cell FCU offers 0-20N / 0-50N / 0-100N / 0-200N / 0-500N / 0-1000N six rated measuring ranges intended for both tension and compression force measurement. The miniature load cell FCU features a M4 tapped hole at the center of the transducer which can be used to mount attachments such as load buttons or eye bolts to fit different applications. Micro Load Cell FCU is applicable for both static and dynamic force measurement. Model FCU can also be modified or customzied as per requirements of our clients.

Miniature Compression Sensor 20kg

Dimensions

Miniature Compression Sensor 5kg
Specifications

Rated Capacity

20N / 2kg / 4.5 lbf
50N / 5kg / 10lbs
100N / 10kg / 22.5lbf
200N / 20kg / 45lb
500N / 50kg / 110lb

100kg / 1kN / 220lb

Rated output 1.5mV/V
Excitation 3-12V
Zero balance ±0.1mV/V
Nonlinearity ±0.5% of rated capacity
Hysteresis ±0.5% of rated capacity
Nonrepeatability ±0.2% of rated capacity
Creep(5min) ±0.1% of rated capacity
Safe overload 150% of rated capacity
Ultimate overload 200% of rated capacity
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.03% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 380±30 ohms
Output resistance 352±5 ohms
Insulation resistance >2000M ohms
Ingress protection IP62
Material of element Stainless steel
Cable Ø3*4000mm 4-core shielded cable
Wiring code

Red--Excitation+   Black--Excitation-
Green--Signal+   White--Signal-

 
Miniature Compression Sensor 2kg 5kg 10kg Press Fit Load Cell 20kg 50kg 100kg
Miniature Compression Sensor 50kg
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of press force load cell FCU is normally around 1.5mV/V.
Power supply of miniature compression sensor FCU is normally within 3-12V.
Load / Capacity is within 0-1.
So the output range of miniature force sensor FCU is normaly within -18mV...+18mV for bidirectional force measurement.
Example: Miniature Load Cell FCU-1000N with 1.5mV/V power by 5V DC,the output range is -7.5mV...+7.5mV proportional to the applied force.
Load cell + Signal amplifier:
The mV output from the loadcell transducer sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.

Example: Compression Force Load Cell FCU-200N working with 0-10V amplifier,the load-output relationship will be 0-200N compressive load VS 0-10V output, 0V output corresponds to 0N, 1V output corresponds to 20N compression load, 2V output corresponds to 40N load,and so on.

Miniature Compression Sensor 100kg 50kg 20kg Press Fit Load Cell 10kg 5kg 2kg

Miniature Compression Sensor 100kg

Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us