Forsentek Co., Limited

Sales & Support
Request A Quote - Email
Select Language
English
Spanish
Home ProductsOther products

Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N

Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N

Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N
Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N

Large Image :  Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N Get Best Price

Product Details:
Place of Origin: China
Brand Name: Forsentek
Model Number: FCU
Payment & Shipping Terms:
Minimum Order Quantity: 2pcs
Packaging Details: Carton
Delivery Time: 3~25 working days
Payment Terms: T/T,Western Union or Paypal
Supply Ability: 2969pcs/month
Detailed Product Description
Usage: Force Measurement Measure Direction: Tension And Compression
Type: Pancake Load Cell Force Range: 20N 50N 100N 200N 500N 1kN
Material: Stainless Steel Connection: M4 Tapped Hole
Output: Analog Load Cell

Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N

Small Size Compression Load Cell FCU is made from stainless steel based on strain gauge technology delivering unamplified mV output which is proportional to the load applied. Small Size Pancake Load Cell FCU offers 0-20N / 0-50N / 0-100N / 0-200N / 0-500N / 0-1000N six rated measuring ranges intended for both tension and compression force measurement. The miniature load cell FCU features a M4 tapped hole at the center of the transducer which can be used to mount attachments such as load buttons or eye bolts to fit different applications. Micro Load Cell FCU is applicable for both static and dynamic force measurement. Model FCU can also be modified or customzied as per requirements of our clients.

Small Size Compression Load Cell 2kg

Dimensions

Miniature Compression Load Cell With M4 Threaded Hole
Specifications

Capacity

20N / 2kg / 4.5 lbf
50N / 5kg / 10lbs
100N / 10kg / 22.5lbf
200N / 20kg / 45lb
500N / 50kg / 110lb

100kg / 1kN / 220lb

Rated output 1.5mV/V
Excitation 3-12V
Zero balance ±0.1mV/V
Nonlinearity ±0.5% R.O.
Hysteresis ±0.5% R.O.
Nonrepeatability ±0.2% R.O.
Creep(5min) ±0.1% R.O.
Safe overload 150% F.S.
Ultimate overload 200% F.S.
Compensated temperature -10...+40oC
Operating temperature -20...+60oC
Temperature shift zero ±0.03% R.O./oC
Temperature shift span ±0.02% R.O./oC
Input resistance 380±30 ohms
Output resistance 352±5 ohms
Insulation resistance >2000M ohms
Ingress protection IP62
Material of element Stainless steel
Cable Ø3*4000mm 4-core shielded cable
Wiring code

Red--Excitation+   Black--Excitation-
Green--Signal+   White--Signal-

 
Compression Load Cell 20N 2kg Small Size Compression Sensor 50N 5kg
Small Size Compression Load Cell 5kg
Brief instruction of Rated output(or Sensitivity):
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of miniature compression load cell FCU is normally around 1.5mV/V.
Power supply of small compression sensor FCU is normally within 3-12V.
Load / Capacity is within 0-1.
So the output range of miniature force sensor FCU is normaly within -18mV...+18mV.
Example: Miniature Load Cell FCU-20N with 1.5mV/V power by 10V DC,the output range is -15mV...+15mV proportional to the applied force.
Load cell + Signal amplifier:
The mV output from the loadcell transducer sometimes cannot be recognized by signal processing units directly,so signal conditioner is introduced to convert mV signal into 0-5V/0-10V/4-20mA for easy signal processing.
Example: Compression Force Load Cell FCU-50N working with 0-5V amplifier,the load-output relationship will be 0-50N compressive load VS 0-5V output,0V output corresponds to 0N, 1V output corresponds to 10N compression load, 2V output corresponds to 20N load,and so on.

Compression Load Cell 2kg 20N Small Size Compression Sensor 5kg 50N

Small Size Compression Load Cell 20N

Click here to download datasheet

Contact Details
Forsentek Co., Limited

Contact Person: Mr. Tarik Lu

Tel: +86 755 84536383

Send your inquiry directly to us