Product Details:
Payment & Shipping Terms:
|
Usage: | Pull Push Force Measurement | Type: | Press Load Cell |
---|---|---|---|
Force Range: | 200N 500N 1kN 2kN 5kN 10kN 20kN | Load Direction: | Tension And Compression |
Mounting: | Flange-to-Flange | Output: | Analog Sensor |
Flange Type Push Load Cell 20kN 10kN 5kN 2kN 1kN 500N 200N Press Force Sensor
Flange to Flange Press Load Cell FFA is made of stainless steel utilizing strain gauge technology to deliver maximum 0.1% non-linearity of full scale.Pull And Push Force Sensor FFA offers 200N / 500N / 1kN / 2kN / 5kN / 10kN / 20kN seven rated capacities to choose from, pull push force transducer FFA can be used for both tension and compression force measurement. Stainless steel construction, flange design, compact size, bidirectional force measurement, high accuracy, Press Force Load Cell FFA offers a perfect force measuring solution for applications such as wire tension control, force distribution analysis, automated control, cylinder thrust force measurement, assembly force monitoring, spring testing, ultrasonic welding clamp force control, hand press force verification, and so on. In addition to the standard specifications, Forsentek is also capable of and willing to provide custom design service to meet requirements of different applications.
Dimensions(Unit in "mm")
Ordering code | Measurement Range | Force direction |
FFA-200N | 0-200N / 0-45lb | Tension/compression |
FFA-500N | 0-500N / 0-112lb | |
FFA-1kN | 0-1000N / 0-225lb | |
FFA-2kN | 0-2000N / 0-450lb | |
FFA-5kN | 0-5000N / 0-1120 lbs | |
FFA-10kN | 0-10kN / 0-2250lb | |
FFA-20kN | 0-20kN / 0-4500 lbs |
Specifications
Capacity |
200N / 20kg / 45 lb 2000N / 200kg / 450lb 20kN / 2000kg / 4.5klb |
Rated output | 2.0 mV/V |
Excitation | 3-15V |
Zero balance | ±0.05mV/V |
Nonlinearity | ±0.1% of capacity |
Hysteresis | ±0.1% of capacity |
Nonrepeatability | ±0.05% of capacity |
Creep(5min) | ±0.05% of capacity |
Safe overload | 150% of capacity |
Ultimate overload | 200% of capacity |
Compensated temperature | -10...+40oC |
Operating temperature | -20...+60oC |
Temperature shift zero | ±0.02% R.O./oC |
Temperature shift span | ±0.02% R.O./oC |
Input resistance | 385±30 ohms |
Output resistance | 350±10 ohms |
Insulation resistance | >2000M ohms |
Ingress protection | IP62 |
Material of element | Stainless steel |
Cable | Ø3*3000mm 4-core shielded |
Wiring code |
Red--Excitation+ Black--Excitation- Green--Signal+ White--Signal- |
Brief instruction of load cell output:
Definition: The signal produced by load cell(or force transducer) when rated load is applied, expressed in terms of mV/V. The rated output indicates the output signal range of a sensor.
Sensor output = (Power supply * Rated output) * Load / Capacity
Rated output of press load cell FFA is normally around 2.0mV/V.
Power supply of flange type press force sensor FFA is normally within 3-15V.
Load / Capacity is within 0-1.
So the output range of push force transducer FFA is normally within -30mV...+30mV for tension and compression force measurement.
Example: Flange Mounted Push Load Cell FFA-2kN with 2.0mV/V sensitivity powered by 10V DC,the output range is -20mV...+20mV.
A load cell amplifier can be used to convert mV signal into -5-5V , 0-10V, 4-20mA.
Example: Press Load Cell FFA-5kN working with 0-10V amplifier,the Force-Voltage relationship will be 0-5kN compression load corresponds to 0-10V voltage output,which is linear regardless of the measurement error.